Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 324
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38661602

RESUMO

BACKGROUND: Postoperative atrial fibrillation (POAF) is associated with increased morbidity and mortality. Epicardial injection of botulinum toxin may suppress POAF. OBJECTIVES: This study sought to assess the safety and efficacy of AGN-151607 for the prevention of POAF after cardiac surgery. METHODS: This phase 2, randomized, placebo-controlled trial assessed the safety and efficacy of AGN-151607, 125 U and 250 U vs placebo (1:1:1), for the prevention of POAF after cardiac surgery. Randomization was stratified by age (<65, ≥65 years) and type of surgery (nonvalvular/valve surgery). The primary endpoint was the occurrence of continuous AF ≥30 seconds. RESULTS: Among 312 modified intention-to-treat participants (placebo, n = 102; 125 U, n = 104; and 250 U, n = 106), the mean age was 66.9 ± 6.8 years; 17% were female; and 64% had coronary artery bypass graft (CABG) only, 12% had CABG + valve, and 24% had valve surgery. The primary endpoint occurred in 46.1% of the placebo group, 36.5% of the 125-U group (relative risk [RR] vs placebo: 0.80; 95% CI: 0.58-1.10; P = 0.16), and 47.2% of the 250-U group (RR vs placebo: 1.04; 95% CI: 0.79-1.37; P = 0.78). The primary endpoint was reduced in the 125-U group in those ≥65 years (RR: 0.64; 95% CI: 0.43-0.94; P = 0.02) with a greater reduction in CABG-only participants ≥65 years (RR: 0.49; 95% CI: 0.27-0.87; P = 0.01). Rehospitalization and rates of adverse events were similar across the 3 groups. CONCLUSIONS: There were no significant differences in the rate of POAF with either dose compared with placebo; however, there was a lower rate of POAF in participants ≥65 years undergoing CABG only and receiving 125 U of AGN-151607. These hypothesis-generating findings require investigation in a larger, adequately powered randomized clinical trial. (Botulinum Toxin Type A [AGN-151607] for the Prevention of Post-operative Atrial Fibrillation in Adult Participants Undergoing Open-chest Cardiac Surgery [NOVA]; NCT03779841); A Phase 2, Multi-Center, Randomized, Double-Blind, Placebo-Controlled, Dose Ranging Study to Evaluate the Efficacy and Safety of Botulinum Toxin Type A [AGN 151607] Injections into the Epicardial Fat Pads to Prevent Post-Operative Atrial Fibrillation in Patients Undergoing Open-Chest Cardiac Surgery; 2017-004399-68).

2.
Circ Heart Fail ; : e010904, 2024 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-38602105

RESUMO

BACKGROUND: Heart transplant (HT) in recipients with left ventricular assist devices (LVADs) is associated with poor early post-HT outcomes, including primary graft dysfunction (PGD). As complicated heart explants in recipients with LVADs may produce longer ischemic times, innovations in donor heart preservation may yield improved post-HT outcomes. The SherpaPak Cardiac Transport System is an organ preservation technology that maintains donor heart temperatures between 4 °C and 8 °C, which may minimize ischemic and cold-induced graft injuries. This analysis sought to identify whether the use of SherpaPak versus traditional cold storage was associated with differential outcomes among patients with durable LVAD undergoing HT. METHODS: Global Utilization and Registry Database for Improved Heart Preservation-Heart (NCT04141605) is a multicenter registry assessing post-HT outcomes comparing 2 methods of donor heart preservation: SherpaPak versus traditional cold storage. A retrospective review of all patients with durable LVAD who underwent HT was performed. Outcomes assessed included rates of PGD, post-HT mechanical circulatory support use, and 30-day and 1-year survival. RESULTS: SherpaPak (n=149) and traditional cold storage (n=178) patients had similar baseline characteristics. SherpaPak use was associated with reduced PGD (adjusted odds ratio, 0.56 [95% CI, 0.32-0.99]; P=0.045) and severe PGD (adjusted odds ratio, 0.31 [95% CI, 0.13-0.75]; P=0.009), despite an increased total ischemic time in the SherpaPak group. Propensity matched analysis also noted a trend toward reduced intensive care unit (SherpaPak 7.5±6.4 days versus traditional cold storage 11.3±18.8 days; P=0.09) and hospital (SherpaPak 20.5±11.9 days versus traditional cold storage 28.7±37.0 days; P=0.06) lengths of stay. The 30-day and 1-year survival was similar between groups. CONCLUSIONS: SherpaPak use was associated with improved early post-HT outcomes among patients with LVAD undergoing HT. This innovation in preservation technology may be an option for HT candidates at increased risk for PGD. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT04141605.

4.
JACC Heart Fail ; 12(3): 438-447, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38276933

RESUMO

BACKGROUND: Extended criteria donor (ECD) hearts available with donation after brain death (DBD) are underutilized for transplantation due to limitations of cold storage. OBJECTIVES: This study evaluated use of an extracorporeal perfusion system on donor heart utilization and post-transplant outcomes in ECD DBD hearts. METHODS: In this prospective, single-arm, multicenter study, adult heart transplant recipients received ECD hearts using an extracorporeal perfusion system if hearts met study criteria. The primary outcome was a composite of 30-day survival and absence of severe primary graft dysfunction (PGD). Secondary outcomes were donor heart utilization rate, 30-day survival, and incidence of severe PGD. The safety outcome was the mean number of heart graft-related serious adverse events within 30 days. Additional outcomes included survival through 2 years benchmarked to concurrent nonrandomized control subjects. RESULTS: A total of 173 ECD DBD hearts were perfused; 150 (87%) were successfully transplanted; 23 (13%) did not meet study transplantation criteria. At 30 days, 92% of patients had survived and had no severe PGD. The 30-day survival was 97%, and the incidence of severe PGD was 6.7%. The mean number of heart graft-related serious adverse events within 30 days was 0.17 (95% CI: 0.11-0.23). Patient survival was 93%, 89%, and 86% at 6, 12, and 24 months, respectively, and was comparable with concurrent nonrandomized control subjects. CONCLUSIONS: Use of an extracorporeal perfusion system resulted in successfully transplanting 87% of donor hearts with excellent patient survival to 2 years post-transplant and low rates of severe PGD. The ability to safely use ECD DBD hearts could substantially increase the number of heart transplants and expand access to patients in need. (International EXPAND Heart Pivotal Trial [EXPANDHeart]; NCT02323321; Heart EXPAND Continued Access Protocol; NCT03835754).


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Adulto , Humanos , Sobrevivência de Enxerto , Insuficiência Cardíaca/cirurgia , Transplante de Coração/métodos , Preservação de Órgãos/métodos , Estudos Prospectivos , Estudos Retrospectivos , Doadores de Tecidos
6.
Ann Thorac Surg ; 117(2): 353-359, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37930297

RESUMO

BACKGROUND: The long-term effectiveness of minithoracotomy over redo median sternotomy for reoperative mitral operation is not well described. Here we present long-term survival after reoperative mitral operation based on operative approach. METHODS: Adults undergoing mitral valve operation with previous sternotomy by redo sternotomy and minithoracotomy were reviewed from our prospectively maintained institutional database from 1997 to 2022. Propensity score matching was performed to compare short- and long-term outcomes. RESULTS: Of 750 consecutive patients, thoracotomy was performed in 503 (67%). Median follow-up was 5.0 years (interquartile range, 0-23 years). Intraoperatively, sternotomy patients were more likely to have central aortic cannulation (205 of 223 [93%] vs 265 of 481 [56%]), cardioplegic arrest (220 of 223 [99%] vs 124 of 481 [26%]), and mitral valve replacement (190 of 223 [85%] vs 358 of 481 [74%]). Thoracotomy patients were older (63 ± 13 vs 58 ± 14 years) with elective presentation (387 of 503 [77%] vs 128 of 247 [52%]). Sternotomy patients were more likely to have endocarditis (52 of 247 [21%] vs 45 of 503 [9%], P < .001). At 10 years, thoracotomy patients experienced improved survival (52% ± 3% vs 46% ± 4%, P = .004). After propensity matching, 10-year survival was significantly higher for thoracotomy patients compared with sternotomy patients (60% ± 5% vs 42% ± 5%, P = .0006). The greatest difference in survival was at the first 6 months after operation (96% ± 1% vs 81% ± 3%, P < .001). CONCLUSIONS: For patients undergoing reoperative mitral valve operation, minimally invasive right anterior thoracotomy can significantly decrease risk of death in the first 6 months, with durable survival benefit out to 10 years. We present a large single-center series to suggest an important opportunity to durably improve outcomes after reoperative mitral operation through wider use of right minithoracotomy.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Esternotomia , Adulto , Humanos , Toracotomia , Valva Mitral/cirurgia , Reoperação , Estudos Retrospectivos , Resultado do Tratamento , Procedimentos Cirúrgicos Minimamente Invasivos
7.
Artif Organs ; 48(2): 157-165, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37814840

RESUMO

BACKGROUND: As heart transplant guidelines evolve, the clinical indication for 73% of durable left ventricular assist device (LVAD) implants is now destination therapy. Although completely magnetically levitated LVAD devices have demonstrated improved durability relative to previous models, LVAD replacement procedures are still required for a variety of indications. Thus, the population of patients with a replaced LVAD is growing. There is a paucity of data regarding the outcomes and risk factors for those patients receiving first-time LVAD replacements. METHODS: The study cohort consisted of all consecutive patients between 2006 and 2020 that received a first-time LVAD replacement at a single institution. Preoperative clinical and laboratory variables were collected retrospectively. The primary endpoint was death or need for an additional LVAD replacement. Data were subjected to Kaplan-Meier, univariate, and multivariate Cox hazard ratio analyses. RESULTS: In total, 152 patients were included in the study, of which 101 experienced the primary endpoint. On multivariate analysis, patients receiving HeartMate 3 (HM3) LVADs as the replacement device showed superior outcomes (HR 0.15, 95% CI 0.065-0.35, p < 0.0001). Independent risk factors for death or need for additional replacement included preoperative extracorporeal membrane oxygenation (ECMO) (HR 4.44, 95% CI 1.87-14.45, and p = 0.00042), increased number of sternotomies (HR 5.20, 95% CI 1.87-14.45, and p = 0.0016), and preoperative mechanical ventilation (HR 1.98, 95% CI 1.01-3.86, and p = 0.045). CONCLUSIONS: Replacement with HM3 showed superior outcomes compared to all other pump types when controlling for both initial pump type and other independent predictors of death or LVAD replacement. Preoperative ECMO, mechanical ventilation, and multiple sternotomies also increased the odds for death or the need for subsequent replacement.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Humanos , Coração Auxiliar/efeitos adversos , Estudos Retrospectivos , Insuficiência Cardíaca/terapia , Transplante de Coração/efeitos adversos , Morbidade , Resultado do Tratamento
8.
Infect Control Hosp Epidemiol ; 45(5): 644-650, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38124539

RESUMO

BACKGROUND: Various water-based heater-cooler devices (HCDs) have been implicated in nontuberculous mycobacteria outbreaks. Ongoing rigorous surveillance for healthcare-associated M. abscessus (HA-Mab) put in place following a prior institutional outbreak of M. abscessus alerted investigators to a cluster of 3 extrapulmonary M. abscessus infections among patients who had undergone cardiothoracic surgery. METHODS: Investigators convened a multidisciplinary team and launched a comprehensive investigation to identify potential sources of M. abscessus in the healthcare setting. Adherence to tap water avoidance protocols during patient care and HCD cleaning, disinfection, and maintenance practices were reviewed. Relevant environmental samples were obtained. Patient and environmental M. abscessus isolates were compared using multilocus-sequence typing and pulsed-field gel electrophoresis. Smoke testing was performed to evaluate the potential for aerosol generation and dispersion during HCD use. The entire HCD fleet was replaced to mitigate continued transmission. RESULTS: Clinical presentations of case patients and epidemiologic data supported intraoperative acquisition. M. abscessus was isolated from HCDs used on patients and molecular comparison with patient isolates demonstrated clonality. Smoke testing simulated aerosolization of M. abscessus from HCDs during device operation. Because the HCD fleet was replaced, no additional extrapulmonary HA-Mab infections due to the unique clone identified in this cluster have been detected. CONCLUSIONS: Despite adhering to HCD cleaning and disinfection strategies beyond manufacturer instructions for use, HCDs became colonized with and ultimately transmitted M. abscessus to 3 patients. Design modifications to better contain aerosols or filter exhaust during device operation are needed to prevent NTM transmission events from water-based HCDs.


Assuntos
Infecção Hospitalar , Infecções por Mycobacterium não Tuberculosas , Infecções por Mycobacterium , Humanos , Infecções por Mycobacterium não Tuberculosas/epidemiologia , Micobactérias não Tuberculosas , Tipagem de Sequências Multilocus , Surtos de Doenças , Infecção Hospitalar/epidemiologia , Infecções por Mycobacterium/epidemiologia
9.
Artigo em Inglês | MEDLINE | ID: mdl-38065238

RESUMO

BACKGROUND: Cardiac metabolism is altered in heart failure and ischemia-reperfusion injury states. We hypothesized that metabolomic profiling during ex situ normothermic perfusion before heart transplantation (HT) would lend insight into myocardial substrate utilization and report on subclinical and clinical allograft dysfunction risk. METHODS: Metabolomic profiling was performed on serial samples of ex situ normothermic perfusate assaying biomarkers of myocardial injury in lactate and cardiac troponin I (TnI) as well as metabolites (66 acylcarnitines, 15 amino acids, nonesterified fatty acids [NEFA], ketones, and 3-hydroxybutyrate). We tested for change over time in injury biomarkers and metabolites, along with differential changes by recovery strategy (donation after circulatory death [DCD] vs donation after brain death [DBD]). We examined associations between metabolites, injury biomarkers, and primary graft dysfunction (PGD). Analyses were performed using linear mixed models adjusted for recovery strategy, assay batch, donor-predicted heart mass, and time. RESULTS: A total of 176 samples from 92 ex situ perfusion runs were taken from donors with a mean age of 35 (standard deviation 11.3) years and a median total ex situ perfusion time of 234 (interquartile range 84) minutes. Lactate trends over time differed significantly by recovery strategy, while TnI increased during ex situ perfusion regardless of DCD vs DBD status. We found fuel substrates were rapidly depleted during ex situ perfusion, most notably the branched-chain amino acids leucine/isoleucine, as well as ketones, 3-hydroxybutyrate, and NEFA (least squares [LS] mean difference from the first to last time point -1.7 to -4.5, false discovery rate q < 0.001). Several long-chain acylcarnitines (LCAC), including C16, C18, C18:1, C18:2, C18:3, C20:3, and C20:4, increased during the perfusion run (LS mean difference 0.42-0.67, q < 0.001). Many LCACs were strongly associated with lactate and TnI. The change over time of many LCACs was significantly different for DCD vs DBD, suggesting differential trends in fuel substrate utilization by ischemic injury pattern. Changes in leucine/isoleucine, arginine, C12:1-OH/C10:1-DC, and C16-OH/C14-DC were associated with increased odds of moderate-severe PGD. Neither end-of-run nor change in lactate or TnI was associated with PGD. CONCLUSIONS: Metabolomic profiling of ex situ normothermic perfusion solution reveals a pattern of fuel substrate utilization that correlates with subclinical and clinical allograft dysfunction. This study highlights a potential role for interventions focused on fuel substrate modification in allograft conditioning during ex situ perfusion to improve allograft outcomes.

10.
JTCVS Tech ; 22: 228-236, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38152175

RESUMO

Objective: We developed a hybrid technique for repairing post-myocardial infarction (MI) ventricular septal defect (VSD) that combines infarct exclusion with patch and a nitinol-mesh septal occluder device (SOD) to provide a scaffold to support the damaged septal wall. Here, we compare outcomes of patients with post-MI VSD repaired using patch only or hybrid patch/SOD. Methods: Patients undergoing post-MI VSD repair at our institution from 2013 to 2022 who received patch alone or patch/SOD repair were analyzed. Primary outcome was survival to hospital discharge. Clinical outcomes and echocardiograms were also analyzed. Results: Over a 9-year period, 24 patients had post-MI VSD repair at our institution with either hybrid patch/SOD (n = 10) or patch only repair (n = 14). VSD size was 18 ± 5.8 mm for patch/SOD and 17 ± 4.6 mm for patch only. In the patch/SOD repair cohort, average size of SOD implant was 23.6 ± 5.6 mm. Mild left ventricular dysfunction was present prerepair and was unchanged postrepair in both groups; however, moderate-to-severe right ventricular (RV) dysfunction was common in both groups before repair. RV function worsened or persisted as severe in 10% of hybrid versus 54% of patch-only patients postrepair. Tricuspid annular systolic excursion and RV:left ventricle diameter ratio, quantitative metrics of RV function, improved after patch/SOD repair. No intraoperative mortality occurred in either group. Postoperative renal, hepatic, and respiratory failure requiring tracheostomy was common in both groups. Survival to hospital discharge in both cohorts was 70%. Conclusions: Post-MI VSD repair with patch/SOD has comparable short-term outcomes with patch alone. Addition of a SOD to patch repair provides a scaffold that may enhance the repair of post-MI VSD with patch exclusion.

11.
JACC Heart Fail ; 2023 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-38032571

RESUMO

Historically, heart transplantation (HT) has relied on the use of traditional cold storage for donor heart preservation. This organ preservation modality has several limitations, including the risk for ischemic and cold-induced graft injuries that may contribute to primary graft dysfunction and poor post-HT outcomes. In recent years, several novel donor heart preservation modalities have entered clinical practice, including the SherpaPak Cardiac Transport System of controlled hypothermic preservation, and the Transmedics Organ Care System of ex vivo perfusion. Such technologies are altering the landscape of HT by expanding the geographic reach of procurement teams and enabling both donation after cardiac death and the use of expanded criteria donor hearts. This paper will review the emerging evidence on the association of these modalities with improved post-HT outcomes, and will also suggest best practices for selecting between donor heart preservation techniques.

13.
Transplant Direct ; 9(11): e1539, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37829247

RESUMO

Background: Hepatitis C virus (HCV) nucleic acid amplification test (NAAT)-positive donors have increased the organ pool. Direct-acting antivirals (DAAs) have led to high rates of treatment success and sustained virologic response (SVR) in recipients with donor-derived HCV infection without significant adverse effects, although variability remains in the timing and duration of antivirals. Methods: This retrospective study analyzed all adult HCV-NAAT-negative transplant recipients who received an organ from HCV-NAAT-positive donors from November 24, 2018, to March 31, 2022, at Duke University Medical Center with protocolized delay of DAA initiation until after hospital discharge, with at least 180-d follow-up on all patients. Transplant and HCV-related outcomes were analyzed. Results: Two hundred eleven transplants (111 kidneys, 41 livers, 34 hearts, and 25 lungs) were performed from HCV-NAAT-positive donors to HCV-NAAT-negative recipients. Ninety percent of recipients became viremic within 7 d posttransplant. Ninety-nine percent of recipients were initiated on pangenotypic DAAs in the outpatient setting a median of 52 d posttransplant, most commonly with 12-wk courses of sofosbuvir-velpatasvir (lungs) and glecaprevir-pibrentasvir (heart, kidney, and liver). Ninety-seven percent of recipients had SVR after a first-line DAA; all ultimately achieved SVR at 12 wk after subsequent treatment courses. The median peak HCV RNA for all organ systems was 2 436 512 IU/mL; the median time from antiviral to undetectable RNA was 48 d, although differences were noted between organ groups. No patient deaths or graft losses were directly attributable to HCV infection. Conclusions: One hundred percent of transplant recipients of HCV-NAAT-positive organs ultimately developed SVR without significant adverse effects when HCV antivirals were initiated in the outpatient setting after transplant hospitalization, suggesting that this real-world treatment pathway is a viable option.

14.
J Cardiothorac Vasc Anesth ; 37(11): 2236-2243, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37586950

RESUMO

OBJECTIVES: To investigate whether recipient administration of thyroid hormone (liothyronine [T3]) is associated with reduced rates of primary graft dysfunction (PGD) after orthotopic heart transplantation. DESIGN: Retrospective cohort study. SETTING: Single-center, university hospital. PARTICIPANTS: Adult patients undergoing orthotopic heart transplantation. INTERVENTIONS: A total of 609 adult heart transplant recipients were divided into 2 cohorts: patients who did not receive T3 (no T3 group, from 2009 to 2014), and patients who received T3 (T3 group, from 2015 to 2019). Propensity-adjusted logistic regression was performed to assess the association between T3 supplementation and PGD. MEASUREMENTS AND MAIN RESULTS: After applying exclusion criteria and propensity-score analysis, the final cohort included 461 patients. The incidence of PGD was not significantly different between the groups (33.9% no T3 group v 40.8% T3 group; p = 0.32). Mortality at 30 days (3% no T3 group v 2% T3 group; p = 0.53) and 1 year (10% no T3 group v 12% T3 group; p = 0.26) were also not significantly different. When assessing the severity of PGD, there were no differences in the groups' rates of moderate PGD (not requiring mechanical circulatory support other than an intra-aortic balloon pump) or severe PGD (requiring mechanical circulatory support other than an intra-aortic balloon pump). However, segmented time regression analysis revealed that patients in the T3 group were less likely to develop severe PGD. CONCLUSIONS: These findings indicated that recipient single-dose thyroid hormone administration may not protect against the development of PGD, but may attenuate the severity of PGD.


Assuntos
Transplante de Coração , Disfunção Primária do Enxerto , Adulto , Humanos , Estudos Retrospectivos , Disfunção Primária do Enxerto/diagnóstico , Disfunção Primária do Enxerto/epidemiologia , Disfunção Primária do Enxerto/etiologia , Transplante de Coração/efeitos adversos , Hormônios Tireóideos , Suplementos Nutricionais
16.
Front Cardiovasc Med ; 10: 1216917, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37408655

RESUMO

Background: Reliable biomarkers for assessing the viability of the donor hearts undergoing ex vivo perfusion remain elusive. A unique feature of normothermic ex vivo perfusion on the TransMedics® Organ Care System (OCS™) is that the donor heart is maintained in a beating state throughout the preservation period. We applied a video algorithm for an in vivo assessment of cardiac kinematics, video kinematic evaluation (Vi.Ki.E.), to the donor hearts undergoing ex vivo perfusion on the OCS™ to assess the feasibility of applying this algorithm in this setting. Methods: Healthy donor porcine hearts (n = 6) were procured from Yucatan pigs and underwent 2 h of normothermic ex vivo perfusion on the OCS™ device. During the preservation period, serial high-resolution videos were captured at 30 frames per second. Using Vi.Ki.E., we assessed the force, energy, contractility, and trajectory parameters of each heart. Results: There were no significant changes in any of the measured parameters of the heart on the OCS™ device over time as judged by linear regression analysis. Importantly, there were no significant changes in contractility during the duration of the preservation period (time 0-30 min, 918 ± 430 px/s; time 31-60 min, 1,386 ± 603 px/s; time 61-90 min, 1,299 ± 617 px/s; time 91-120 min, 1,535 ± 728 px/s). Similarly, there were no significant changes in the force, energy, or trajectory parameters. Post-transplantation echocardiograms demonstrated robust contractility of each allograft. Conclusion: Vi.Ki.E. assessment of the donor hearts undergoing ex vivo perfusion is feasible on the TransMedics OCS™, and we observed that the donor hearts maintain steady kinematic measurements throughout the duration.

17.
Circulation ; 148(17): 1316-1329, 2023 10 24.
Artigo em Inglês | MEDLINE | ID: mdl-37401479

RESUMO

BACKGROUND: Right ventricular failure (RVF) is a leading driver of morbidity and death after major cardiac surgery for advanced heart failure, including orthotopic heart transplantation and left ventricular assist device implantation. Inhaled pulmonary-selective vasodilators, such as inhaled epoprostenol (iEPO) and nitric oxide (iNO), are essential therapeutics for the prevention and medical management of postoperative RVF. However, there is limited evidence from clinical trials to guide agent selection despite the significant cost considerations of iNO therapy. METHODS: In this double-blind trial, participants were stratified by assigned surgery and key preoperative prognostic features, then randomized to continuously receive either iEPO or iNO beginning at the time of separation from cardiopulmonary bypass with the continuation of treatment into the intensive care unit stay. The primary outcome was the composite RVF rate after both operations, defined after transplantation by the initiation of mechanical circulatory support for isolated RVF, and defined after left ventricular assist device implantation by moderate or severe right heart failure according to criteria from the Interagency Registry for Mechanically Assisted Circulatory Support. An equivalence margin of 15 percentage points was prespecified for between-group RVF risk difference. Secondary postoperative outcomes were assessed for treatment differences and included: mechanical ventilation duration; hospital and intensive care unit length of stay during the index hospitalization; acute kidney injury development including renal replacement therapy initiation; and death at 30 days, 90 days, and 1 year after surgery. RESULTS: Of 231 randomized participants who met eligibility at the time of surgery, 120 received iEPO, and 111 received iNO. Primary outcome occurred in 30 participants (25.0%) in the iEPO group and 25 participants (22.5%) in the iNO group, for a risk difference of 2.5 percentage points (two one-sided test 90% CI, -6.6% to 11.6%) in support of equivalence. There were no significant between-group differences for any of the measured postoperative secondary outcomes. CONCLUSIONS: Among patients undergoing major cardiac surgery for advanced heart failure, inhaled pulmonary-selective vasodilator treatment using iEPO was associated with similar risks for RVF development and development of other postoperative secondary outcomes compared with treatment using iNO. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT03081052.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Insuficiência Cardíaca , Humanos , Administração por Inalação , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Epoprostenol/uso terapêutico , Insuficiência Cardíaca/tratamento farmacológico , Insuficiência Cardíaca/cirurgia , Óxido Nítrico , Vasodilatadores
18.
N Engl J Med ; 388(23): 2121-2131, 2023 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-37285526

RESUMO

BACKGROUND: Data showing the efficacy and safety of the transplantation of hearts obtained from donors after circulatory death as compared with hearts obtained from donors after brain death are limited. METHODS: We conducted a randomized, noninferiority trial in which adult candidates for heart transplantation were assigned in a 3:1 ratio to receive a heart after the circulatory death of the donor or a heart from a donor after brain death if that heart was available first (circulatory-death group) or to receive only a heart that had been preserved with the use of traditional cold storage after the brain death of the donor (brain-death group). The primary end point was the risk-adjusted survival at 6 months in the as-treated circulatory-death group as compared with the brain-death group. The primary safety end point was serious adverse events associated with the heart graft at 30 days after transplantation. RESULTS: A total of 180 patients underwent transplantation; 90 (assigned to the circulatory-death group) received a heart donated after circulatory death and 90 (regardless of group assignment) received a heart donated after brain death. A total of 166 transplant recipients were included in the as-treated primary analysis (80 who received a heart from a circulatory-death donor and 86 who received a heart from a brain-death donor). The risk-adjusted 6-month survival in the as-treated population was 94% (95% confidence interval [CI], 88 to 99) among recipients of a heart from a circulatory-death donor, as compared with 90% (95% CI, 84 to 97) among recipients of a heart from a brain-death donor (least-squares mean difference, -3 percentage points; 90% CI, -10 to 3; P<0.001 for noninferiority [margin, 20 percentage points]). There were no substantial between-group differences in the mean per-patient number of serious adverse events associated with the heart graft at 30 days after transplantation. CONCLUSIONS: In this trial, risk-adjusted survival at 6 months after transplantation with a donor heart that had been reanimated and assessed with the use of extracorporeal nonischemic perfusion after circulatory death was not inferior to that after standard-care transplantation with a donor heart that had been preserved with the use of cold storage after brain death. (Funded by TransMedics; ClinicalTrials.gov number, NCT03831048.).


Assuntos
Morte Encefálica , Transplante de Coração , Obtenção de Tecidos e Órgãos , Adulto , Humanos , Sobrevivência de Enxerto , Preservação de Órgãos , Doadores de Tecidos , Morte , Segurança do Paciente
20.
Am J Transplant ; 23(7): 1048-1057, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37059177

RESUMO

Nontuberculous mycobacteria are emerging pathogens, yet data on the epidemiology and management of extrapulmonary nontuberculous mycobacteria infections in orthotopic heart transplantation (OHT) and ventricular assist device (VAD) recipients are scarce. We retrospectively reviewed records of OHT and VAD recipients who underwent cardiac surgery at our hospital and developed Mycobacterium abscessus complex (MABC) infection from 2013 to 2016 during a hospital outbreak of MABC linked to heater-cooler units. We analyzed patient characteristics, medical and surgical management, and long-term outcomes. Ten OHT patients and 7 patients with VAD developed extrapulmonary M. abscessus subspecies abscessus infection. The median time from presumed inoculation during cardiac surgery to the first positive culture was 106 days in OHT and 29 days in VAD recipients. The most common sites of positive cultures were blood (n = 12), sternum/mediastinum (n = 8), and the VAD driveline exit site (n = 7). The 14 patients diagnosed when alive received combination antimicrobial therapy for a median of 21 weeks, developed 28 antibiotic-related adverse events, and underwent 27 surgeries. Only 8 (47%) patients survived longer than 12 weeks after diagnosis, including 2 patients with VAD who experienced long-term survival after an explantation of infected VADs and OHT. Despite aggressive medical and surgical management, OHT and VAD patients with MABC infection experienced substantial morbidity and mortality.


Assuntos
Transplante de Coração , Coração Auxiliar , Infecções por Mycobacterium não Tuberculosas , Mycobacterium abscessus , Humanos , Coração Auxiliar/efeitos adversos , Estudos Retrospectivos , Transplante de Coração/efeitos adversos , Infecções por Mycobacterium não Tuberculosas/tratamento farmacológico , Infecções por Mycobacterium não Tuberculosas/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...